Stock Code: 601869.SH / 06869.HK

High Temperature Fibre (HTF)

Data transmission, high power laser delivery and sensors require special reliability at demanding environment conditions. A special challenge is a changing temperature, extreme heat or extreme cold conditions for a fibre when used as fire detector, temperature sensor or for data transmission in certain special industrial applications. YOFC offers HTF for medium and high temperature environment requirements with the temperature up to 300 ℃ .
Applications

• The applications of YOFC HTF are demanded in environments such as mining industry, aerospace, military, oil&gas industry and medical that requires a maximum protection of the fibre at very high temperatures.

Product standards

1. Special Polymer Coated High Temperature Fibre

Operation temperature: long term, -65 ℃ to +150 ℃ ;intermittent, up to 200 ℃

Cladding diameter range from 200μm to 660μm, customizedNA and coating diameter

• Coating diameter (125μm cladding fibres): 245±10μ

• Coating diameter (200~660μm cladding fibres): NA: Customized

2. Optimized Polyimide Coated High Temperature Fibre

Operation temperature: in long term, -65 ℃ to +300 ℃ ;intermittent, up to 350 ℃

Cladding diameter range from 200μm to 660μm, customizedNA and coating diameter

• Coating diameter (125μm cladding fibres): 155±5μm

• Coating diameter ( ≤ 220μm cladding fibres): NA: Customized

Characteristics

• Excellent high temperature stabilit

• Excellent optical and geometrical propertie

• Customized profile and sizes

Specifications

Specifications-1

Fibre Type

HT 9/125-14/250(150)

HT 9/125-14/155(300)

Part No.

HT1210-A

HT1510-B

Optical Properties

Mode Field Diameter@1310nm (μm)

9.2±0.4

9.2±0.4

Mode Field Diameter@1550nm (μm)

10.4±0.8

10.4±0.8

Fibre Cut-off Wavelength (nm)

1180~1330

1180~1330

Attenuation@1310nm (dB/km)

≤0.4

≤1.0

Attenuation@1550nm (dB/km)

≤0.25

≤0.8

Geometrical Properties

Cladding Diameter (μm)

125.0±1.0

125.0±2.0

Coating Diameter (μm)

245.0±10.0

155.0±5.0

Cladding Non-circularity (%)

≤1.0

≤1.0

Core/ Cladding Concentricity Error(μm)

≤0.8

≤0.8

Coating/ Cladding Concentricity Error(μm)

≤12.0

 

Mechanical Properties

Proof Test (kpsi)

100

100

Operating Temperature (℃)

-65 ~ +150 Short term +200

-65 ~ +300 Short term +350

Coating Type

Special Polymer

Polyimide

Specifications-2

Fibre Type

HTG 50/125-
20/250(150)
HTG 62.5/125-
27/250(150)
HTG 50/125-
20/155(300)
HTG 62.5/125-
27/155(300)

Part No.

HT2312-B

HT2215-A

HT2512-B

HT2515-B

Optical Properties

*Attenuation@850 nm (dB/km)

≤3.0

≤3.0

≤4.0

≤4.0

*Attenuation@1300 nm (dB/km)

≤1.0

≤1.0

≤2.0

≤2.0

Bandwidth@850 (MHz·km)

≥150

≥150

≥150

≥150

Bandwidth@1300 nm (MHz·km)

≥300

≥300

≥300

≥300

NA

0.200±0.015

0.275±0.015

0.200±0.015

0.275±0.015

Geometrical Properties

Core Diameter (μm)

50±2.5

62.5±2.5

50±3

62.5±3

Cladding Diameter (μm)

125±2

125±2

125±2

125±2

Coating Diameter (μm)

245±10

245±10

155±5

155±5

Cladding Non-circularity (%)

≤1

≤1

≤2

≤2

Core/Cladding Offset (μm)

≤1.5

≤1.5

≤1.5

≤1.5

Coating/Cladding Offset (μm)

≤12

≤12

 

 

Mechanical Properties

Proof Test (kpsi)

100

100

100

100

Operating Temperature (℃)

-65 ~ +150 Short term +200

-65 ~ +300 Short term +350

Coating Type

Special Polymer

Polyimide

*For attenuation measurement, the fibre is wound with near zero tension onto a greater than 36cm diameter measurement spool.

*Customized products are available upon customer request, such as different geometrical parameters, bandwidth, NA, higher proof test level, etc.

 