For the Telecommunication Industry
• DWDM amplifiers
• CATV amplifiers
• 980nm or 1480nm pumps
• Terrestrial and Submarine telecommunications
• Defense/Military/Aerospace
For the Telecommunication Industry
• DWDM amplifiers
• CATV amplifiers
• 980nm or 1480nm pumps
• Terrestrial and Submarine telecommunications
• Defense/Military/Aerospace
• Excellent spectral uniformity
• High power conversion efficiency and low noise design
• Industry leading fibre geometry
• Low PMD
• DLPC9 dual-layer coating to ensure excellent mechanical properties
• Good performance of anti-hydrogen loss
• Lower splice loss

|
Fibre Type |
EDF3/6/125-23 |
EDF7/6/125-23 |
EDF13/6/125-23 |
EDF22/6/125-23 |
EDF36/6/125-23 |
|---|---|---|---|---|---|
|
Part No. |
ED1011-A |
ED1012-A |
ED1013-A |
ED1015-A |
ED1016-A |
|
Absorption Peak Coefficient at 1532 nm (Max. [1530 ‒ 1534 nm]) |
|||||
|
Specified Value |
2~4 dB/m |
4~9 dB/m |
10~15 dB/m |
19~25 dB/m |
32~40 dB/m |
|
Typical |
3 dB/m |
7 dB/m |
13 dB/m |
22 dB/m |
36 dB/m |
|
Application |
C Band |
C Band |
C & L Band |
C & L Band |
C & L Band |
|
Fibre Type |
EDF3/6/125-23 |
EDF7/6/125-23 |
EDF13/6/125-23 |
EDF22/6/125-23 |
EDF36/6/125-23 |
|---|---|---|---|---|---|
|
Part No. |
ED1011-A |
ED1012-A |
ED1013-A |
ED1015-A |
ED1016-A |
|
Optical Properties |
|||||
|
*Absorption Peak 1532nm (Max.[1530~1534 nm]) Specified Value (dB/m) |
2 ~ 4 |
4 ~ 9 |
10 ~ 15 |
19 ~ 25 |
32 - 40 |
|
*Absorption Peak 1532nm (Max.[1530~1534 nm]) Typical (dB/m) |
3 |
7 |
13 |
22 |
36 |
|
Absorption Reproducibility (%) (250m) |
≤ 2.5 |
≤ 2.5 |
≤ 2.5 |
≤ 2.5 |
≤ 2.5 |
|
Background Attenuation(Min.[1100~1300 nm]) (dB/km) |
≤ 10 |
≤ 10 |
≤ 10 |
≤ 10 |
≤ 10 |
|
Background Attenuation(Min.[1100~1300 nm]) Typical (dB/km) |
≤ 6 |
≤ 6 |
≤ 6 |
≤ 6 |
≤ 6 |
|
Macro-bend Induced Attenuation (100 m, 15 mm diameter, λ< 1620 nm) (dB) |
≤ 0.1 |
≤ 0.1 |
≤ 0.1 |
≤ 0.1 |
≤ 0.1 |
|
*Cutoff Wavelength (nm) |
≤ 1300 |
≤ 1300 |
≤ 1300 |
≤ 1300 |
≤ 1300 |
|
*MFD 1550 nm (μm) |
5.4 ± 0.7 |
5.4 ± 0.7 |
5.4 ± 0.7 |
5.4 ± 0.7 |
5.4 ± 0.7 |
|
NA |
0.23 ± 0.02 |
0.23 ± 0.02 |
0.23 ± 0.02 |
0.23 ± 0.02 |
0.23 ± 0.02 |
|
Splicing Loss (with G.652 at 1300 & 1700 nm) (dB) |
≤ 0.2 |
≤ 0.2 |
≤ 0.2 |
≤ 0.2 |
≤ 0.2 |
|
PMD (100 m) (ps) |
≤ 0.25 |
≤ 0.25 |
≤ 0.25 |
≤ 0.25 |
≤ 0.25 |
|
Geometrical Properties |
|||||
|
Cladding Diameter (μm) |
125.0±1.0 |
125.0±1.0 |
125.0±1.0 |
125.0±1.0 |
125.0±1.0 |
|
Coating Diameter (μm) |
250.0±7.0 |
250.0±7.0 |
250.0±7.0 |
250.0±7.0 |
250.0±7.0 |
|
Core/Cladding Concentricity (μm) |
≤ 0.6 |
≤ 0.6 |
≤ 0.6 |
≤ 0.6 |
≤ 0.6 |
|
Cladding/Coating Concentricity (μm) |
≤ 12.5 |
≤ 12.5 |
≤ 12.5 |
≤ 12.5 |
≤ 12.5 |
|
Mechanical Properties |
|||||
|
Proof Test (kpsi) |
100 |
100 |
100 |
100 |
100 |
|
Delivery Length (± 5 m)(m) |
250, 500, 1000 |
250, 500, 1000 |
250, 500, 1000 |
250, 500, 1000 |
250, 500, 1000 |
|
Environmental Properties |
|||||
|
Storage Temperature (℃) |
-40~+75 |
-40~+75 |
-40~+75 |
-40~+75 |
-40~+75 |
|
Operating Temperature Range (℃) |
-5~ +75 |
-5~ +75 |
-5~ +75 |
-5~ +75 |
-5~ +75 |
|
Storage Humidity (Non Condensing)(%) |
5 ~ 95 |
5 ~ 95 |
5 ~ 95 |
5 ~ 95 |
5 ~ 95 |
|
Operating Humidity (Non Condensing)(%) |
5 ~ 95 |
5 ~ 95 |
5 ~ 95 |
5 ~ 95 |
5 ~ 95 |