Stock Code: 601869.SH / 06869.HK

Micro Cables for Indoor Installation with LSZH Sheath (GCYFZY)

Optical fibres are housed in loose tubes that are made of high-modulus plastic and filled with tube filling compound. The tubes (and fillers) are stranded around a non-metallic central strength member and surrounded with dry water-blocking material to form a cable core. A thin outer green (RAL 6018) or gray (RAL 7001) LSZH (low smoke zero halogen) sheath is extruded outside the core.

Characteristics
  • Small size and light weight
  • Low smoke emission rates and halogen-free
  • Tube filling compound providing key protection for fibres
  • High fibre density, allowing full use of duct holes
  • Allowing to blow by phases to reduce initial investment
  • Allowing to blow out and replace with new cables to keep technical superiority
  • Avoiding destructive excavations and no need to pay high fees for deploying permission, applicable for constructions in crowded metropolitan area networks
  • Allowing to cut micro ducts anywhere anytime for branch without influences on other cables, saving manholes, hand holes and cable joints
  • The cables of this specification, intended for internal laying will be classified for reaction to fire with EuroclassCca-s1b, d1, a1 according to the tests indicated in CEI EN 50575
Technical Characteristics

Type

Maximum O.D.

(mm)

Maximum weight (kg/km)

Tensile load

 (N)

Crushing

(N/100mm)

Impact

(J, 3 impacts, R = 300 mm)

Number of tubes/fibre count per tube

GCYFZY-12B6a1

8.2

75

600

1000

3

1/12

GCYFZY-24B6a1

8.2

75

600

1000

3

2/12

GCYFZY-48B6a1

8.2

80

600

1000

3

4/12

GCYFZY-96B6a1 200um

8.2

80

600

1000

3

4/24

GCYFZY-144B6a1 200um

8.2

80

1000

1000

3

6/24

 

Environmental Characteristics
  • Transport/storage temperature: -30℃ to +70℃
Applications

The cable can be used as the drop cable of feeder segments in FTTH networks and can be laid by air blowing to connect the branch point with the access point for subscribers. The cable is also applicable in metropolitan area networks and access networks.

Delivery Length

Standard length: 2,000m; other lengths are also available.