Stock Code: 601869.SH / 06869.HK

Hybrid Optical and Electrical Stranded Loose Tube Cable (GDTS)

Single-mode/multimode fibres are housed in loose tubes that are made of high-modulus plastic and filled with tube filling compound. In the center of cable is a metallic strength member. The tubes and copper wires (of required specifications) are stranded around the central strength member to form a cable core. The core is filled with cable filling compound and armored with corrugated steel tape. Then, a PE sheath is extruded.
Features

• Accurate process control ensuring good mechanical and temperature performances 
• Optical and electrical hybrid design, solving the problem of power supply and signal transmission and providing the centralized monitoring and maintenance of power for equipment
• Improving manageability of power and reducing coordination and maintenance of power supply
• Reducing procurement costs and saving construction costs
• Mainly used to connect BBU and RRU in DC remote power supply system for distributed base station 
• Applicable to duct and aerial installations 

Technical Characteristic

Type

O.D.

(mm)

Weight

(Kg/km)

Tensile strength

Long/short term (N)

Crush

Long/short term

(N/100mm)

Structure

GDTS-02-24Xn+2×1.5

11.6

157

600/1500

300/1000

Structure I

GDTS-02-24Xn+2×2.5

12.5

190

600/1500

300/1000

Structure I

GDTS-02-24Xn+2×4.0

14.6

241

600/1500

300/1000

Structure II

GDTS-02-24Xn+2×5.0

15.0

282

600/1500

300/1000

Structure II

GDTS-02-24Xn+2×6.0

15.7

300

600/1500

300/1000

Structure II

GDTS-02-24Xn+2×8.0

16.9

383

600/1500

300/1000

StructureII

Note:

1. Xn refers to fibre type.

2. 2*1.5/2*2.5/2*4.0/2*6.0/2*8.0 indicates the number and size of copper wires.

3. Hybrid cables with different numbers and sizes of copper wires can be provided on request.

4. Hybrid cables with different fibre counts can be provided on request.

Electrical Performance of Conductor

Cross section

(mm2)

Max. DC resistance of

single conductor

(20 ℃)(Ω/km)

Insulation resistance (20℃)(MΩ.km)

Dielectric strength KV, DC 1minDielectric strength KV, DC 1min

Between each conductor and other

metal members connected in cable

Between

conductors

Between conductor

and metallic armor

Between conductor

and steel wire

1.5

13.3

 

No less than 5,000

 

5

 

5

 

3

2.5

7.98

4.0

4.95

5.0

3.88

6.0

3.30

8.0

2.47

Environmental Characteristics

• Transport/storage temperature: -40℃ to +70℃

Delivery Length

• Standard length: 2,000m; other lengths are also available. 

Suggestions and feedback