Parameters | Index | |||
---|---|---|---|---|
Product Type | MPC2-P12-S322 | MPC2-P12-S333 | MPC2-P12-S344 | MPC2-P12-S355 |
Signal Operating Wavelength (nm) |
1000-1100, Typical 1064 |
|||
Pump Operating Wavelength (nm) |
800-1000 |
|||
Input Pump Port |
||||
Core/Cladding Diameter (μm) |
105/125 |
200/220 |
||
Numerical Aperture |
0.22 |
0.22 |
||
Input Signal Port |
||||
Fibre Type |
DCF |
|||
Core/Cladding Diameter (μm) |
10/130 |
20/130 |
20/400 |
30/250 |
Output Port |
||||
Fibre Type |
DCF |
|||
Core/Cladding Diameter (μm) |
10/130 |
20/130 |
20/400 |
30/250 |
Optical Properties |
||||
Pump Efficiency (%) |
>90 (Typical 93) |
|||
M2 |
≤1.3 |
|||
Insertion Loss (dB) |
<0.5 ( Typical 0.3) |
|||
Optical Isolation (dB) |
≥25 (Typical 30) |
|||
Max Pump Power (W) |
Typical 10 |
|||
Environmental Properties |
||||
Operating Temperature (℃) |
-5 to +70 |
|||
Operating Relative Humidity (%) |
5-95 |
|||
Storage Temperature (℃) |
-40 to +85 |
|||
Appearance |
||||
Dimensions (mm) |
5×5×50,Φ3.5×54, 8×12×75 | |||
Active Fibre Length (m) |
1.0 |