Medium/Long Span ADSS Tension Set is composed of Dead-end component and structural reinforcing rods, the materials are aluminum-clad steel and galvanized steel wire, it is mainly used for ADSS installation between strain tower/pole, corner tower/pole and terminal tower/pole which span length is larger than 200m with RTS of the cable is larger than 15kN. Medium Span ADSS Tension set is used for installation span length between 200m-400m, Long Span ADSS Tension set is used for installation span length longer than 400m.
Type | Available Dia. of Cable | Reference Span(m) | |
---|---|---|---|
Min.(mm) | Max.(mm) | ||
NJA 950/200 |
8.6 |
9.5 |
100-200 |
NJA 1050/200 |
9.6 |
10.5 |
100-200 |
NJA 1150/200 |
10.6 |
11.5 |
100-200 |
NJA 1250/200 |
11.6 |
12.5 |
100-200 |
NJA 1350/200 |
12.6 |
13.5 |
100-200 |
NJA 1450/200 |
13.6 |
14.5 |
100-200 |
NJA 1050/300 |
9.6 |
10.5 |
200-300 |
NJA 1150/300 |
10.6 |
11.5 |
200-300 |
NJA 1250/300 |
11.6 |
12.5 |
200-300 |
NJA 1350/300 |
12.6 |
13.5 |
200-300 |
NJA 1450/300 |
13.6 |
14.5 |
200-300 |
NJA 1150/400 |
10.6 |
11.5 |
300-400 |
NJA 1250/400 |
11.6 |
12.5 |
300-400 |
NJA 1350/400 |
12.6 |
13.5 |
300-400 |
NJA 1450/400 |
13.6 |
14.5 |
300-400 |
NJA 1550/400 |
14.6 |
15.5 |
300-400 |
NJA 1650/400 |
15.6 |
16.5 |
300-400 |
NJA 1250/500 |
11.6 |
12.5 |
400-500 |
NJA 1350/500 |
12.6 |
13.5 |
400-500 |
NJA 1450/500 |
13.6 |
14.5 |
400-500 |
NJA 1550/500 |
14.6 |
15.5 |
400-500 |
NJA 1650/500 |
15.6 |
16.5 |
400-500 |
NJA 1350/600 |
12.6 |
13.5 |
500-600 |
NJA 1450/600 |
13.6 |
14.5 |
500-600 |
NJA 1550/600 |
14.6 |
15.5 |
500-600 |
NJA 1650/600 |
15.6 |
16.5 |
500-600 |
NJA 1750/600 |
16.6 |
17.5 |
500-600 |
NJA 1350/700 |
12.6 |
13.5 |
600-800 |
NJA 1450/700 |
13.6 |
14.5 |
600-800 |
NJA 1550/700 |
14.6 |
15.5 |
600-800 |
NJA 1650/700 |
15.6 |
16.5 |
600-800 |
NJA 1750/700 |
16.6 |
17.5 |
600-800 |
NJA 1550/800 |
14.6 |
15.5 |
800-1000 |
NJA 1650/800 |
15.6 |
16.5 |
800-1000 |
NJA 1750/800 |
16.6 |
17.5 |
800-1000 |
NJA 1850/800 |
17.6 |
18.5 |
800-1000 |
NJA 1550/1000 |
14.6 |
15.5 |
1000 |
NJA 1650/1000 |
15.6 |
16.5 |
1000 |
NJA 1750/1000 |
16.6 |
17.5 |
1000 |
NJA 1850/1000 |
17.6 |
18.5 |
1000 |
Note:
The material for Short Span ADSS Tension Set is aluminum-clad steel and galvanized steel wire; it is mainly used for ADSS installation between strain tower/pole, corner tower/pole, mid-joint tower/pole and terminal tower/pole which span length is less than 100m.
Type | Available Dia. of Cable | Reference Span | |
---|---|---|---|
Min.(mm) | Max.(mm) | ||
NJA 1050/100 | 9.6 | 10.5 | Less than 100m span |
NJA 1150/100 | 10.6 | 11.5 | Less than 100m span |
NJA 1250/100 | 11.6 | 12.5 | Less than 100m span |
NJA 1350/100 |
12.6 |
13.5 | Less than 100m span |
NJA 1450/100 |
13.6 |
14.5 | Less than 100m span |
Note: