- Atomic energy
- Medical care
- Petroleum
- Natural gas
- Scientific research
| Fibre type | Wavelength (nm) | Condition | RD1310 G2 (HT) | RD SM-G3 | RD SM-G3(YH) | RD SM-G3(HD) |
|---|---|---|---|---|---|---|
| Part No. | - | - | RD1311-D | RD1012-A | RD1012-B | RD1012-C |
| Optical properties | ||||||
| Attenuation (dB/km) | 1310 | - | ≤0.45 | ≤0.4 | ≤0.4 | ≤0.4 |
| 1550 | - | ≤0.53 | ≤0.3 | ≤0.3 | ≤0.3 | |
| Zero dispersion wavelength (nm) | - | - | 1287~1337 | 1303~1324 | 1303~1324 | 1303~1324 |
| Zero dispersion slope (ps/nm²·km) | - | - | ≤0.1 | ≤0.091 | ≤0.091 | ≤0.091 |
| Maximum value of single fibre (ps/km) | - | - | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 |
| Fibre link design value | - | - | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 |
| Cable cut-off wavelength (nm) | - | - | ≤1290 | ≤1290 | ≤1260 | ≤1260 |
| Mode field diameter (μm) | 1310 | - | 7.5~9.5 | 8.6~9.6 | 8.6~9.5 | 8.6~9.5 |
| 1550 | - | 8.0~10.0 | 9.6~10.9 | 9.9~10.9 | 9.6~10.9 | |
| Geometrical properties | ||||||
| Cladding diameter (μm) | - | - | 125.0±1.0 | 125.0±1.0 | 124.5±0.4 | 125.0±1.0 |
| Cladding non-circularity (%) | - | - | ≤0.7 | ≤1.0 | ≤1.0 | ≤1.0 |
| Coating diameter (μm) | - | - | 245.0±10.0 | 245.0±10.0 | 245.0±5.0 | 245.0±10.0 |
| Core/cladding concentricity error (μm) | - | - | ≤12.0 | ≤12.0 | ≤8.0 | ≤12.0 |
| Coating non-circularity (%) | - | - | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 |
| Coating non-circularity error (μm) | ≤0.6 | ≤1.0 | ≤0.6 | ≤1.0 | ||
| Curl (radial) | - | - | ≥2.0 | ≥2.0 | ≥2.0 | ≥2.0 |
| Environmental properties | ||||||
| Temperature-humidity cycling induced attenuation (dB/km) |
1310, 1550 | -10℃~85℃, 89%RH | ≤0.1 | ≤0.1 | ≤0.1 | ≤0.1 |
| Temperature dependence induced attenuation (dB/km) |
65℃~85℃ | ≤0.1 | ≤0.1 | ≤0.1 | ≤0.1 | |
| Water soak/dependence induced attenuation (dB/km) | - | 23℃, 30 days | ≤0.1 | ≤0.1 | ≤0.1 | ≤0.1 |
| Damp heat dependence induced attenuation (dB/km) |
- | 85℃, 89%RH, 30 days | ≤0.1 | ≤0.1 | ≤0.1 | ≤0.1 |
| Dry heat aging (dB/km) | - | 85℃, 30 days | ≤0.1 | ≤0.1 | ≤0.1 | ≤0.1 |
| Temperature shock test (dB/km) | - | -70℃~125℃, 30℃/min, 5 cycles | - | - | ≤0.3 | - |
| Storage temperature test (dB/km) | - | 120 hours at 70℃ 120 hours at 125℃ |
- | - | ≤0.3 | - |
| Temperature cycle test (dB/km) | - | -70°C~+125°C, 2~5°C/min, 5 cycles | - | - | ≤0.3 | - |
| Macro-bending performance | ||||||
| Bending radius | - | Number of turns | - | - | - | - |
| 30mm | 1310 | 100 | - | ≤0.1 | ≤0.1 | ≤0.1 |
| 1550 | - | ≤0.5 | ≤0.5 | ≤0.5 | ||
| Mechanical performance | ||||||
| Proof test level(kpsi) | - | Off-line | ≥100 | ≥100 | ≥100 | ≥100 |
| Coating strip force (N) | - | Average value | 1.0~5.0 | 1.0~5.0 | 1.0~5.0 | 1.0~5.0 |
| - | Peak value | 1.3~8.9 | 1.3~8.9 | 1.3~8.9 | 1.3~8.9 | |
| Dynamic fatigue parameter (n) | - | - | ≥20 | ≥20 | ≥20 | ≥20 |
| Radiation resistance | ||||||
| Test according to TIA/EIA 455-64(Db/100m) | 1310 | Induced attenuation under continuous radiation conditions with a total dose of 50 Krad and a dose rate of 0.1 rad/s (at 25°C) |
- | ≤0.3 | ≤0.3 | ≤0.3 |
| 1310, 1550 | Induced attenuation under continuous radiation conditions with a total dose of 2000 Gy and a dose rate of 0.5 Gy/s (at 25°C) |
≤0.9 | ≤0.8 | ≤0.8 | ≤0.5 | |
| 1310 | Induced attenuation under continuous radiation conditions with a total dose of 200000 Gy and a dose rate of 0.5 Gy/s (at 25°C) |
≤2.0 | ≤1.5 | ≤1.5 | ≤1.0 | |
| 1550 | ≤2.5 | ≤2.0 | ≤2.0 | ≤1.5 | ||
| 1310 | Induced attenuation under continuous radiation conditions with a total dose of 1 MGy and a dose rate of 1.25 Gy/s (at 25°C) |
- | - | - | -1.2 | |
| 1550 | - | - | - | -1.8 | ||