Characteristic Impedance |
Velocity |
Capacitance |
Insulation Resistance |
Insulation Voltage |
Jacket Spark Test Voltage |
---|---|---|---|---|---|
50 ± 2 Ω |
0.88 |
76 pF/m |
>5000 MΩ.km |
15000 V |
10000 V |
|
Frequency(MHz) |
Attenuation dB/100m(+20℃) |
Coupling Loss(50%/95%) dB |
---|---|---|---|
M Band |
75 |
0.57 |
67/75 |
150 |
0.95 |
71/77 |
|
350 |
1.52 |
67/75 |
|
450 |
1.71 |
68/75 |
|
700 |
2.00 |
64/69 |
|
800 |
2.57 |
63/71 |
|
900 |
2.76 |
65/72 |
|
960 |
2.86 |
60/66 |
|
H Band |
700 |
2.19 |
73/78 |
800 |
2.29 |
65/70 |
|
900 |
2.48 |
65/69 |
|
960 |
2.57 |
65/69 |
|
1800 |
4.10 |
61/67 |
|
1900 |
4.38 |
61/68 |
|
2200 |
5.24 |
61/66 |
|
2400 |
6.00 |
60/65 |
|
2600 |
6.95 |
60/63 |
|
2620 |
7.71 |
60/65 |
Weight |
Maximum Pulling Force |
Single Bending |
Repeated Bending |
Operating Temperature Range |
Installation Temperature Range |
---|---|---|---|---|---|
1000kg/km |
2500N |
500 mm |
700 mm |
-40-+85℃ |
PE: -40℃ LSZH: -20℃ |
1.Corrugated Cu-tube
2.Foamed PE Dielectric
3.Longitudinally Wrapped Copper Strip
4.PE Jacket or LSZH