Meet national standards such as YD/T788-2011, GB/T2423-2008, GB/ 13873-1998, GB/T9286-1998 and international standards such as IEC 61300-3-15, IEC61300-3-16, IEC 61300-3-17, IEC61300-3-23.
• Open frame, line side in the front and equipment side in the back, partition management
• 72-core fibre management unit at the line side, modular design, convenient operation
• 96-core rotatable adapter panel at the equipment side, convenient operation and maintenance
• The cable can be introduced from above or below and be free to allocate
• Reliable cable entry, fixing and protection device, suitable for ribbon and non ribbon optical fibre cable
• No cross patch cord route, multi-jumper channel, to realize the patch cord separation, and to ensure that the fibre bending radius is greater than 37.5mm
• Overlong patch cord stored by special storage tray, clean and tidy, easy to find by meticulous management
• Operating temperature: -40℃ to +60℃
• Ambient humidity: ≤95%(+40℃ )
• Atmospheric pressure: 70 kPa to 106 kPa
• Insulation resistance: The insulation resistance between grounding device and cabinet metal components is not less than 2 x 104 m Ω / 500 V(DC)
• Withstand Voltage: The withstand voltage between grounding device and cabinet metal components is not less than 3000V(DC)/1min
• Insertion loss: ≤0.3dB
• Return loss: PC type ≥45dB, UPC type ≥50dB, APC type ≥60dB
Name |
Type |
Dimension H×W×D(mm) |
Capacity(core) |
Working Environment |
Note |
|
---|---|---|---|---|---|---|
Line side |
Equipment side |
|||||
Main Optical Distribution Frames |
GPX035-M-20 |
2000×840×600 |
576 |
480 |
Indoor |
Open frame |
GPX035-M-22 |
2200×840×600 |
720 |
576 |
|||
GPX035-M-26 |
2600×840×600 |
864 |
672 |