Cable Type: MSLYWYZ-50-22
1 Smooth Copper Tube
2 Foamed PE Dielectric
3 Longitudinally Wrapped Copper Strip
4 LSZH

Cable Type: MSLYWYZ-50-22
1 Smooth Copper Tube
2 Foamed PE Dielectric
3 Longitudinally Wrapped Copper Strip
4 LSZH

|
Characteristic Impedance |
Velocity |
Capacitance |
Insulation Resistance |
Insulation Voltage |
Jacket Spark Test Voltage |
|---|---|---|---|---|---|
|
50 ± 2 Ω |
0.88 |
76 pF/m |
>5000 MΩ.km |
10000 V |
8000 V |
|
Frequency (MHz) |
75~200 |
698-960 |
1700-1900 |
1920-2025 |
2110-2170 |
2300-2700 |
3300-3700 |
|---|---|---|---|---|---|---|---|
|
VSWR (Max) |
1.30 |
1.30 |
1.40 |
1.40 |
|||
|
Frequency (MHz) |
Attenuation dB/100m(+20℃) |
Coupling Loss (95%) dB |
|---|---|---|
|
75 |
1.4 |
75 |
|
100 |
1.5 |
80 |
|
150 |
1.7 |
85 |
|
700 |
3.7 |
85 |
|
800 |
4.2 |
82 |
|
900 |
4.6 |
80 |
|
1800 |
7.6 |
74 |
|
1900 |
8.0 |
74 |
|
2000 |
8.4 |
73 |
|
2100 |
8.6 |
72 |
|
2400 |
9.5 |
72 |
|
2600 |
10.5 |
70 |
|
2700 |
11.9 |
70 |
|
3300 |
12.8 |
70 |
|
3400 |
14.0 |
70 |
|
3500 |
15.0 |
70 |
|
3600 |
17.2 |
70 |
|
3700 |
19.8 |
74 |
Note: Attenuation tolerance 5%; Coupling Loss tolerance ±5dB
| Maximum Pulling Force |
Single Bending |
Repeated |
Operating Temperature Range |
Installation Temperature Range |
|---|---|---|---|---|
|
1200N |
250 mm |
300 mm |
-20℃ to +70℃ |
-20℃ |
|
|
Inner |
Dielectric | Outer Conductor |
Jacket |
|---|---|---|---|---|
| 7/8" Radiating Type Leaky Coaxial Cable(M/H Band) |
9.0 mm |
23.2 mm |
23.5 mm |
27.5 mm |
| 7/8" Radiating Type Leaky Coaxial Cable(HK Band) |
9.0 mm |
23.2 mm |
23.5 mm |
27.5 mm |
| 1/2" Radiating Type Leaky Coaxial Cable(H Band) |
4.8 mm |
12.2 mm |
13.2 mm |
15.8 mm |
| 1 1/4" Radiating Type Leaky Coaxial Cable(M/HBand) |
13.1 mm |
33.0 mm |
33.5 mm |
37.0 mm |
| 1 1/4" Radiating Type Leaky Coaxial Cable(HK Band) |
13.1 mm |
33.0 mm |
33.5 mm |
37.0 mm |
| 1 1/4”Radiating Type Leaky Coaxial Cable (L Band) |
13.1 mm |
33.0 mm |
33.5 mm |
37.0 mm |
| 1/2" Radiating Type Le akage Cable For Coal Mine |
4.8 mm |
12.5 mm |
13.1 mm |
15.6 mm |
| 7/8" Radiating Type Leakage Cable For Coal Mine |
9.0 mm |
22.8 mm |
23.5 mm |
27.2 mm |
| 1 1/4" Radiating Type Leaky Coaxial Cable (Horizontal polarization) |
13.1 mm |
33.0 mm |
33.5 mm |
37.0 mm |
| 1 5/8" Radiating Type Leaky Coaxial Cable (Z Band) |
17.6 mm |
43.0 mm |
43.6 mm |
47.5 mm |
| 1 5/8" Radiating Type Leaky Coaxial Cable |
17.6 mm |
43.0 mm |
43.6 mm |
47.5 mm |
| 1 5/8" Radiating Type Leaky Coaxial Cable (Train System Ⅲ Type) |
17.6 mm |
43.0 mm |
43.6 mm |
47.5 mm |