Cable Type: HLRHTCYZ-50-32L
1 Corrugated Cu-tube
2 Foamed PE Dielectric
3 Longitudinally Wrapped Copper Strip
4 PE Jacket or LSZH

Cable Type: HLRHTCYZ-50-32L
1 Corrugated Cu-tube
2 Foamed PE Dielectric
3 Longitudinally Wrapped Copper Strip
4 PE Jacket or LSZH

|
Characteristic Impedance |
Velocity |
Capacitance |
Insulation Resistance |
Insulation Voltage |
Jacket Spark Test Voltage |
|---|---|---|---|---|---|
|
50 ± 2 Ω |
0.88 |
76 pF/m |
>10000 MΩ.km |
10000 V |
10000 V |
|
Frequency (MHz) |
1700-1900 |
1920-2025 |
2110-2200 |
2300-2400 |
2515-2675 |
3300-3700 |
|---|---|---|---|---|---|---|
|
VSWR (Max) |
1.30 |
1.40 |
||||
|
Frequency (MHz) |
200m |
250m |
300m |
350m |
|---|---|---|---|---|
|
1700 |
80 |
84 |
86 |
89 |
|
1800 |
79 |
81 |
83 |
85 |
|
1900 |
79 |
81 |
83 |
85 |
|
2000 |
79 |
81 |
83 |
85 |
|
2200 |
79 |
81 |
84 |
86 |
|
2400 |
78 |
81 |
84 |
86 |
|
2600 |
78 |
80 |
83 |
86 |
|
2700 |
79 |
81 |
83 |
86 |
|
3300 |
80 |
83 |
85 |
87 |
|
3400 |
80 |
83 |
85 |
87 |
|
3500 |
80 |
83 |
86 |
88 |
|
3600 |
80 |
83 |
87 |
91 |
|
3700 |
82 |
86 |
90 |
94 |
|
Weight |
Maximum Pulling Force |
Single Bending |
Repeated |
Operating Temperature Range |
Installation Temperature Range |
|---|---|---|---|---|---|
|
610kg/km |
2000N |
300 mm |
400 mm |
-55℃ to +85℃ |
PE: -40℃ LSZH: -20℃ |
|
Test Method For Fame Retardancy |
Test Methods For Smoke Index |
Test Methods For Toxicity Index |
System Loss Test Method |
|---|---|---|---|
|
IEC 60332-1 Polarization Method |
IEC 61034 |
IEC 60754-1/IEC 60754-2 |
YD/T 2491 |
| 1700-3700MHz |
Vertical polarization |
|---|
| Passed | ||
|---|---|---|
| ISO 9001 |
ISO 14001 |
ISO 45001 |
|
|
Inner |
Dielectric | Outer Conductor |
Jacket |
|---|---|---|---|---|
| 7/8" Radiating Type Leaky Coaxial Cable(M/H Band) |
9.0 mm |
23.2 mm |
23.5 mm |
27.5 mm |
| 7/8" Radiating Type Leaky Coaxial Cable(HK Band) |
9.0 mm |
23.2 mm |
23.5 mm |
27.5 mm |
| 1/2" Radiating Type Leaky Coaxial Cable(H Band) |
4.8 mm |
12.2 mm |
13.2 mm |
15.8 mm |
| 1 1/4" Radiating Type Leaky Coaxial Cable(M/HBand) |
13.1 mm |
33.0 mm |
33.5 mm |
37.0 mm |
| 1 1/4" Radiating Type Leaky Coaxial Cable(HK Band) |
13.1 mm |
33.0 mm |
33.5 mm |
37.0 mm |
| 1 1/4”Radiating Type Leaky Coaxial Cable (L Band) |
13.1 mm |
33.0 mm |
33.5 mm |
37.0 mm |
| 1/2" Radiating Type Le akage Cable For Coal Mine |
4.8 mm |
12.5 mm |
13.1 mm |
15.6 mm |
| 7/8" Radiating Type Leakage Cable For Coal Mine |
9.0 mm |
22.8 mm |
23.5 mm |
27.2 mm |
| 1 1/4" Radiating Type Leaky Coaxial Cable (Horizontal polarization) |
13.1 mm |
33.0 mm |
33.5 mm |
37.0 mm |
| 1 5/8" Radiating Type Leaky Coaxial Cable (Z Band) |
17.6 mm |
43.0 mm |
43.6 mm |
47.5 mm |
| 1 5/8" Radiating Type Leaky Coaxial Cable |
17.6 mm |
43.0 mm |
43.6 mm |
47.5 mm |
| 1 5/8" Radiating Type Leaky Coaxial Cable (Train System Ⅲ Type) |
17.6 mm |
43.0 mm |
43.6 mm |
47.5 mm |